CalculateMyRoof

OSB Thickness for a Roof

The thinnest OSB or plywood the code allows over your rafters, with and without edge clips, and the minimums shingle makers set.

By Marko Visic, BSc Physics · Updated November 25, 2026

Bars of each panel rating's longest roof span, filled without edge support and outlined with it, 16/0 to 60/32, against rafters 16 and 24 in apart
Each span rating's longest roof span from the code's table, filled without edge support and outlined with it: a panel works where its bar reaches past your rafter spacing.

Drawing: CalculateMyRoof · CC BY 4.0 · How to reuse

OSB thickness for a roof depends on how far apart the rafters are. Over rafters 24 in apart, the 2024 IRC allows 7/16 in OSB rated 24/16 with nothing under its edges, or 3/8 in rated 24/0 with H-clips or blocking; over rafters 16 in apart, 3/8 in rated 16/0.[1] Plywood follows the same table.[2] Owens Corning and TAMKO want at least 7/16 in OSB under their shingles.[3][4]

The thinnest panel at each rafter spacing

Find your rafter or truss spacing, center to center, and read across: first the thinnest panel the table allows with nothing under its long edges, then the thinnest with edge support, which is lumber blocking, tongue-and-groove edges or panel edge clips.[1]

Thinnest roof panel by rafter spacing, without and with edge support, from the code's span table
Rafters on centerNo edge supportWith edge support
12 in16/0, 3/8 in16/0, 3/8 in[1]
16 in16/0, 3/8 in16/0, 3/8 in[1]
19.2 in20/0, 3/8 in20/0, 3/8 in[1]
24 in24/16, 7/16 in24/0, 3/8 in[1]
32 in40/20, 19/32 or 5/8 in32/16, 15/32 or 1/2 in[1]
48 in60/32, 7/8 in48/24, 23/32 or 3/4 in[1]

One more panel spans 24 in on its own: a 24/0 panel 15/32 or 1/2 in thick.[1] The roof sheathing calculator makes the same pick for your spacing and counts the panels, rows and clips for the roof.

How span ratings work

The 2024 IRC limits roof panels to the spans in its Table R503.2.1.1(1) or in APA E30.[2] The table sorts panels by span rating, and the first number of a rating is the longest roof span the panel allows with edge support, in inches: a 32/16 panel spans 32 in with it and 28 in without.[1]

The spans hold for panels at least 24 in wide, laid long side across the rafters and continuous over two or more spans.[1] The loads assume a 10 psf dead load; under a heavier one, the live load is reduced to match.[1]

Do you need H-clips?

Only where the panel's span without edge support is shorter than your rafter spacing. Over rafters 24 in apart, a 24/0 panel at 3/8 in spans 20 in on its own, so it needs them; a 24/16 at 7/16 in spans 24 in without them.[1] The clips go one midway between each pair of rafters, two where the rafters are 48 in apart; blocking or tongue-and-groove edges do the same job.[1] APA notes that spacer-type edge clips can be used on roofs.[5]

Why some charts say 5/8 in for 24 in rafters

That figure is for boards: the code's Table R803.1 sets lumber sheathing over rafters 24 in apart at 5/8 in net, and 1 1/2 in tongue-and-groove from 48 to 72 in.[2] Plywood and OSB follow R803.2.2 and the span table instead, where 7/16 in rated 24/16 covers the same spacing.[1][2]

What shingle and metal roof makers ask for

Shingle makers print their own deck minimums in their installation instructions, and two of the three read here want thicker OSB than plywood:

Roof deck minimums in shingle makers' installation instructions
ShinglePlywood, at leastOSB, at least
Owens Corning Duration3/8 in7/16 in[3]
TAMKO Heritage3/8 in, exterior grade7/16 in, exterior grade[4]
GAF Timberline3/8 in3/8 in[6]

So under Owens Corning or TAMKO shingles, the 3/8 in OSB the code allows over rafters 16 in apart falls short, and 7/16 in is the minimum.[1][3] GAF also takes board decks, the boards at least 1 in nominal thick and at most 6 in wide, spaced no more than 1/8 in.[6]

Metal panels carry their own listings. The Texas Department of Insurance's product evaluations put Metal Sales' Classic Rib over 15/32 or 5/8 in plywood,[7] its Magna-Loc over 5/8 in plywood[8] and its Strongpanel over a solid 7/16 in OSB deck,[9] and Mueller's CWH over 15/32 in plywood,[10] each on framing no more than 24 in on center. The metal roof calculator counts the panels and screws for two of them.

OSB or plywood?

For span, the code treats them the same: both are wood structural panels, grade-marked to DOC PS 1, DOC PS 2 or the Canadian standards, and both read the same table.[2] A panel exposed only on its underside may be Exposure 1; one left out in the weather for good must be exterior grade.[2] The makers' minimums do tell them apart: Owens Corning and TAMKO accept 3/8 in plywood but not OSB thinner than 7/16 in.[3][4]

Gaps and nailing

APA recommends a 1/8 in gap at panel ends and edges, a recommendation rather than a requirement,[5] while Owens Corning requires 1/8 to 1/4 in under Duration shingles.[3] Nails sit 3/8 in from the panel ends and edges.[11]

The code nails panels 3/8 to 3/4 in thick with 8d common or RSRS-01 ring shank nails, 6 in apart at the panel edges and at every rafter between.[12] Where the design wind speed is over 130 mph in Exposure B or 110 mph in Exposure C, they go 4 in apart at gable end framing and on rafters within 48 in of the roof's edges and ridge.[12]

Snow and heavier roofs

A thicker rating carries more live load. Over rafters 24 in apart, the table gives 40 psf for 24/16, 70 psf for 32/16, 130 psf for 40/20 and 175 psf for 48/24.[1] Compare the live load at your spacing with the roof snow load your building department designs for. The snow guide and the roof load calculator show what snow weighs on a roof.

Your local code governs

These are the 2024 IRC figures. Your jurisdiction may adopt a different edition or amend it, and the code your building department enforces, with the roofing product's instructions, governs the real roof.

Common questions

Is 7/16 OSB okay for a roof?

Yes, when it is rated 24/16: then it spans rafters up to 24 in apart without edge support and carries 40 psf of live load at that spacing.[1] It also meets the 7/16 in OSB minimum of Owens Corning and TAMKO.[3][4]

Should I use 1/2 or 5/8 plywood for roofing?

Either covers rafters 24 in apart without edge support: a panel 1/2 in thick rated 32/16 spans 28 in on its own and carries 70 psf at that spacing, and a 5/8 in panel rated 40/20 spans 32 in and carries 130 psf.[1] Pick by the live load your roof has to carry.

Can I use 1/2 inch OSB for roof sheathing?

Yes, over rafters up to 24 in apart, with or without edge support: the table's 1/2 in panels, rated 32/16 or 24/0, both span that far on their own.[1]

Is 3/4 OSB as strong as 3/4 plywood?

For roof spans the code doesn't tell them apart: a 3/4 in panel rated 48/24 spans 48 in with edge support and 36 in without, whether it is OSB or plywood.[1][2]

What thickness OSB for a shed roof?

The table goes by span, not by building: a shed with rafters 24 in apart reads the same row as a house, 7/16 in rated 24/16 without clips.[1] A shingle maker's own minimum still applies under its shingles.

Methodology & sources

The span table, its notes, the roof sheathing sections and the nailing are the 2024 IRC's, read on ICC's site; the deck minimums come from each maker's installation instructions and the metal panel decks from TDI's product evaluations. For each spacing, the spacing table takes the thinnest rating whose span reaches it, without and with edge support, the same lookup the roof sheathing calculator makes; the page gives the code's answers rather than reprinting its table, which is on ICC's site, linked below. Every figure is checked against its source entry on each build.

Sources

  1. [1] International Code Council. 2024 International Residential Code, Chapter 5: Floors (Oct 2026 version). Section R503.2.1.1. Retrieved Nov 20, 2026. codes.iccsafe.org
  2. [2] International Code Council. 2024 International Residential Code, Chapter 8: Roof-Ceiling Construction (Oct 2026 version). Sections R803.1, R803.2.1, R803.2.1.1, R803.2.2. Retrieved Nov 20, 2026. codes.iccsafe.org
  3. [3] Owens Corning. Duration Series Shingles installation instructions. Roof Deck. Retrieved Nov 20, 2026. owenscorning.com
  4. [4] TAMKO Building Products. Application Instructions for Heritage, Dallas, Frederick, Joplin and Phillipsburg plants (Rev. 07/31/2024). p. 2, 1. Roof Deck. Retrieved Nov 20, 2026. tamko.com
  5. [5] APA – The Engineered Wood Association. Builder Tips: Prevent Buckling with Proper Spacing (Form M300). Retrieved Nov 20, 2026. apawood.org
  6. [6] GAF. Timberline installation instructions for HDZ, UHDZ, ASII and CS (RESTL622-0423). p. 2, Roof Deck. Retrieved Nov 20, 2026. gaf.com
  7. [7] Texas Department of Insurance. Product Evaluation RC-161 (Metal Sales Classic Rib). Limitations: Roof Framing. Retrieved Nov 13, 2026. tdi.texas.gov
  8. [8] Texas Department of Insurance. Product Evaluation RC-197 (Metal Sales Magna-Loc). Limitations: Roof Framing. Retrieved Nov 13, 2026. tdi.texas.gov
  9. [9] Texas Department of Insurance. Product Evaluation RC-406 (Metal Sales Strongpanel over OSB). Limitations: Roof Framing. Retrieved Nov 13, 2026. appscenter.tdi.texas.gov
  10. [10] Texas Department of Insurance. Product Evaluation RC-653 (Mueller CWH standing seam over plywood). Limitations: Roof Deck; Installation: Roof Framing Members. Retrieved Nov 13, 2026. appscenter.tdi.texas.gov
  11. [11] APA – The Engineered Wood Association. Builder Tips: Proper Installation of APA Rated Sheathing for Roof Applications (Form N335P, July 2013). Retrieved Nov 20, 2026. apawood.org
  12. [12] International Code Council. 2024 International Residential Code, Chapter 6: Wall Construction (Oct 2026 version). Section R602.3. Retrieved Nov 20, 2026. codes.iccsafe.org

Change log: first published November 25, 2026.

Related