CalculateMyRoof

Wind Load Calculator for Roofs

Enter the wind speed for your address and the roof's span: the calculator gives the uplift each rafter or truss connection has to hold under the residential code.

By Marko Visic, BSc Physics · Updated November 25, 2026

A rafter on a wall with a strap and an upward arrow: at 120 mph in Exposure B, a 32 ft span at 24 in on center pulls 240 lb per connection
Wind lifts the roof, and each rafter or truss connection to the wall has to hold its share. The code's table gives that force for the wind speed, exposure, span, spacing and pitch.

Drawing: CalculateMyRoof · CC BY 4.0 · How to reuse

For a house, the wind load that matters on the roof is uplift: the pull on each rafter or truss where it sits on the wall. At 120 mph in Exposure B, a roof spanning 32 ft with trusses 24 in on center and a pitch of 5:12 or steeper pulls 240 lb on every connection, by Table R802.11 of the residential code.[1]

Roof uplift calculator

Uplift per connection from the table for Exposure B, 24 in on center, 32 ft span, 120 mph and a pitch of 5:12 or steeper: 240 lb.[1]

Each rafter or truss needs a connection to the wall that resists at least that uplift.[1]

Find your wind speed

The code works from the ultimate design wind speed on its wind map, and your building department lists the figure for your area.[2] For a single address, the ASCE Hazard Tool looks up ASCE 7 wind speeds along with the other site loads; check its figure against the one your building department lists.[3] Type the speed in miles per hour into the calculator. The table covers 110 to 140 mph.[1]

Pick the exposure

Exposure describes the ground around the house, from towns and woods to open water.[2]

  • Exposure B: towns, suburbs and woods, with many obstructions the size of a house or larger. The code assumes B unless the site fits another category.[2]
  • Exposure C: open country with scattered obstructions, generally under 30 ft, reaching more than 1,500 ft from the house in any direction; also a house in a suburb that backs onto such open ground for more than 600 ft.[2]
  • Exposure D: flat ground facing wind off open water, mud flats, salt flats or ice for at least 5,000 ft.[2] The uplift table has no D column: the code reads the Exposure C value at the next higher speed.[1]

The same roof at 120 mph pulls 462 lb per connection in Exposure C against 240 lb in Exposure B.[1]

What the table assumes

The forces hold for a mean roof height of up to 33 ft and roof overhangs of up to 24 in, and they include an allowance for 15 psf of roof and ceiling dead load.[1] A taller house or a longer overhang is outside the table. Between its rows and columns the code allows linear interpolation, and the calculator prints each step.[1]

Pitch matters too, though less on the example roof. A roof flatter than 5:12 sees more pull: at 120 mph it pulls 268 lb per connection under 5:12 against 240 lb at 5:12 or steeper.[1]

Corners and hip roofs

A connection more than 8 ft from any building corner may be designed for less: 240 × 0.75 = 180 lb on the example roof.[1] A hip roof at 5:12 or steeper may use a factor of 0.70 instead, 240 × 0.70 = 168 lb, but never both reductions together.[1]

When nails are enough

Every rafter needs a connection to the wall that resists the uplift from the table, and trusses follow their design drawings, which may use the same table.[1][1] The code lets rafters and trusses be fastened by its ordinary nailing schedule, Table R602.3(1), in two cases:[1]

  • The uplift is 200 lb or less and the wall framing's specific gravity is at least 0.42.[1]
  • The wind speed is 115 mph or less, the exposure is B, the pitch is 5:12 or steeper, the span is at most 32 ft and the spacing at most 24 in on center.[1]

The calculator tells you when your roof meets either one.

Where the code stops

The residential code's wind rules end at 140 mph in a special wind region, and in the areas its map marks for wind design; there the house is designed to the AWC Wood Frame Construction Manual, ICC 600, ASCE 7, AISI S230 or the building code.[2] Spans past the last row of the uplift table, or speeds past its last column, fall back on accepted engineering practice.[1]

Common questions

How do you calculate the wind load on a roof?

For a house built to the residential code, look up the uplift per rafter or truss in Table R802.11 from the wind speed, exposure, span, spacing and pitch, as the calculator does.[1] A full pressure calculation follows ASCE 7 and is an engineer's job.[2]

What uplift does a 120 mph wind put on a roof?

On the example roof, 32 ft across with trusses 24 in apart and a pitch of 5:12 or steeper, 240 lb per connection in Exposure B and 462 lb in Exposure C.[1] Per foot of wall, the code lets you read the 12 in row instead: 120 lb per foot in Exposure B.[1]

Do I need hurricane ties?

You need a connection that resists the table's uplift unless the roof meets one of the two exceptions above; the code sets the force, not the product.[1] Check a connector's rated uplift against the number from the calculator.

Does a hip roof see less uplift?

At 5:12 or steeper the code lets a hip roof use 0.70 of the table force, the larger of the table's two reductions.[1]

Methodology & sources

Every force comes from Table R802.11 of the 2024 International Residential Code, read on the International Code Council's site in November 2026 and checked number by number against that page; the footnotes give the interpolation, the Exposure D rule and the two reductions.[1] The calculator returns one cell of the table, or the interpolation between cells, for your numbers and never prints the table, which is the Council's copyright. It does not compute ASCE 7 pressures. Every result prints its equation.

Sources

  1. [1] International Code Council. 2024 International Residential Code, Chapter 8: Roof-Ceiling Construction (Oct 2026 version). Sections R802.11, R802.11.1, R802.11.2. Retrieved Nov 17, 2026. codes.iccsafe.org
  2. [2] International Code Council. 2024 International Residential Code, Chapter 3: Building Planning (Oct 2026 version). Sections R301.2.1, R301.2.1.1, R301.2.1.4. Retrieved Nov 17, 2026. codes.iccsafe.org
  3. [3] American Society of Civil Engineers. ASCE Hazard Tool. site description. Retrieved Nov 17, 2026. ascehazardtool.org

Change log: first published November 25, 2026.

Related

By Marko Visic, BSc Physics. Updated November 25, 2026.