CalculateMyRoof

Ice and Water Shield Calculator

Work out the leak barrier your eaves and valleys take, by the building code and GAF's instructions, in courses and rolls, and the felt or synthetic underlayment for the rest of the roof.

By Marko Visic, BSc Physics · Updated November 25, 2026

The overhang runs from the outside of the wall to the roof edge. The roof area is the sloped area of the whole roof; leave it empty to skip the underlayment. Prices are optional and yours; nothing is sent anywhere.

Eave strip: from the eave edge over the overhang and the wall to 24 in past the wall's inside face, along the slope, (12 + 6 + 24) × √(6² + 12²) ÷ 12 = 46.96 in.[2] A 36 in roll lapped 3 in at the side takes (46.96 − 36) ÷ (36 − 3) = 0.33 → 1 more course, 1 + 1 = 2 in all.[2][3]

Membrane: 2 × 80 + 30 = 190 ft of runs along the eaves and down the valleys, each valley one centered roll width.[2] In pieces of at most 20 ft lapped 6 in at the ends, 6 ÷ 12 = 0.5 ft, it takes (190 − 0.5) ÷ (20 − 0.5) = 9.72 → 10 pieces, so 190 + (10 − 1) × 0.5 = 194.5 ft of membrane, or 194.5 × 36 ÷ 12 = 583.5 sq ft.[2][3]

Rolls: 194.5 ÷ 66.7 = 2.92 → 3 rolls of GAF StormGuard, 36 in × 66.7 ft.[3]

Rest of the deck: 2,000 − 80 × 46.96 ÷ 12 − 30 × 36 ÷ 12 = 1,596.93 sq ft.[3] In GAF FeltBuster, lapped 3 in at the sides and 6 in at the ends, a roll covers (250 − 6 ÷ 12) × (48 − 3) ÷ 12 = 935.63 sq ft, so 1,596.93 ÷ 935.63 = 1.71 → 2 rolls.[4][5]

How much ice and water shield do I need? You need enough to cover each eave from its edge to 24 in past the inside of the wall, measured along the slope, plus every valley.[2] With a 12 in overhang, a 6 in wall and a 6:12 pitch, that is (12 + 6 + 24) × √(6² + 12²) ÷ 12 = 46.96 in, two courses of a 36 in roll.[2][3] On 80 ft of eaves and 30 ft of valleys that is 194.5 ft of membrane, or 194.5 ÷ 66.7 = 2.92 → 3 rolls of GAF StormGuard.[3]

Eave section at 6:12: a 12 in overhang, 6 in wall and 24 in inside it make a 46.96 in strip up the slope, 2 courses of 36 in lapped 3 in
The leak barrier runs from the eave edge over the overhang and the wall to past the wall's inside face, measured up the slope; a second course laps the first.

Drawing: CalculateMyRoof · CC BY 4.0 · How to reuse

How it works

Enter the length of all the eaves, the overhang from the outside of the wall to the roof edge, the wall's thickness, the pitch and the length of all the valleys. The calculator measures the strip each eave needs along the slope, counts the courses of the roll that cover it with their side laps, adds the valleys, and lays the runs in pieces lapped end to end. That gives the membrane in feet and square feet, and the rolls.

With the roof's area it takes away the eave and valley strips and counts the underlayment for the rest of the deck: GAF FeltBuster, a synthetic, or TAMKO No. 15 or No. 30 felt.[6] With your prices it adds up the cost. For another maker's leak barrier, pick "Another roll" and enter its width, length and laps from its instructions.

Where the code requires an ice barrier

The 2024 IRC requires an ice barrier under asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate, and wood shingles and shakes where the local jurisdiction records a history of ice forming along the eaves (R905.1.2). Your building department fills in the code's climate table, which says whether that includes your town.[1]

The code runs the barrier from the lowest roof edge to at least 24 in inside the exterior wall line, and at 8:12 and steeper at least 36 in along the slope.[1] GAF's StormGuard instructions take it to at least 24 in past the interior warm wall, so the calculator adds the wall's thickness; enter 0 for the wall to measure from the wall line instead.[2] Measured from the wall line, the worked example's strip would be (12 + 24) × √(6² + 12²) ÷ 12 = 40.25 in instead of 46.96 in.[1]

The 36 in minimum matters on a steep roof with a short run: with no overhang and the wall line as the start, an 8:12 roof needs 24 × √(8² + 12²) ÷ 12 = 28.84 in by the first rule, so the second sets it at 36 in.[1]

Worked example

A roof with 80 ft of eaves, a 12 in overhang, a 6 in wall, a 6:12 pitch and 30 ft of valleys needs an eave strip of (12 + 6 + 24) × √(6² + 12²) ÷ 12 = 46.96 in along the slope.[2] A 36 in roll, each added course lapping the one below by 3 in, takes (46.96 − 36) ÷ (36 − 3) = 0.33 → 1 more course, 1 + 1 = 2 in all.[2][3]

The runs come to 2 × 80 + 30 = 190 ft, each valley taking one roll width centered on it.[2] GAF's instructions cut the roll into pieces of at most 20 ft and lap them 6 in, 6 ÷ 12 = 0.5 ft, so the runs take (190 − 0.5) ÷ (20 − 0.5) = 9.72 → 10 pieces and 190 + (10 − 1) × 0.5 = 194.5 ft of membrane, 194.5 × 36 ÷ 12 = 583.5 sq ft.[2][3] At 66.7 ft a roll that is 194.5 ÷ 66.7 = 2.92 → 3 rolls.[3]

On a 2,000 sq ft roof the rest of the deck is 2,000 − 80 × 46.96 ÷ 12 − 30 × 36 ÷ 12 = 1,596.93 sq ft.[3] GAF FeltBuster lapped 3 in at the sides and 6 in at the ends covers (250 − 6 ÷ 12) × (48 − 3) ÷ 12 = 935.63 sq ft a roll, so 1,596.93 ÷ 935.63 = 1.71 → 2 rolls.[4][5] TAMKO No. 15 felt takes 1,596.93 ÷ 408 = 3.91 → 4 rolls.[6]

How much a roll covers

Roll sizes and coverage from each maker's documents
ProductRollCovers
GAF StormGuard leak barrier36 in x 66.7 ft200 sq ft, laps not counted[3]
GAF FeltBuster synthetic48 in x 250 ft1,000 sq ft, laps not counted[4]
TAMKO No. 15 felt36 in x 144 ft408 sq ft, laid as TAMKO instructs[6]
TAMKO No. 30 felt36 in x 72 ft204 sq ft, laid as TAMKO instructs[6]

GAF's coverage leaves the laps out, so the calculator takes them off itself: a StormGuard course lapped 3 in adds 36 − 3 = 33 in up the roof, and each piece loses 6 in at its end.[2][3] TAMKO's felt coverage is for felt laid by its instructions, so the calculator divides by it as printed.[6]

Underlayment for the rest of the roof

Asphalt shingles need a slope of at least 2:12, and from 2:12 up to 4:12 the code wants two layers of underlayment.[1] FeltBuster does that by overlapping each course 25.5 in, which brings a roll down to (250 − 6 ÷ 12) × (48 − 25.5) ÷ 12 = 467.81 sq ft.[4][5] For felt on those slopes the calculator counts two layers, twice the area over the roll's coverage.[1]

What does ice and water shield cost?

We found no public primary source for leak barrier or underlayment prices, so this page prints none. Enter your supplier's price per roll and the calculator multiplies it out and gives the leak barrier's cost per sq ft of membrane. For a whole roof, the roof estimate counts the rest of the materials.

Ice and water shield formulas

  • Eave strip (in, along the slope) = (overhang + wall + 24) × √(pitch² + 12²) ÷ 12, at least 36 at 8:12 and steeper.[1][2]
  • Courses = 1 + (strip − roll width) ÷ (roll width − side lap), the fraction rounded up.[2]
  • Runs (ft) = courses × eave length + valley length; pieces = (runs − end lap) ÷ (piece − end lap), rounded up.[2]
  • Membrane (ft) = runs + (pieces − 1) × end lap; rolls = membrane ÷ roll length, rounded up.[3]
  • Underlayment (rolls) = (roof area − eave strip − valley strips) ÷ coverage per roll, with two layers of felt below 4:12.[1]

Common questions

How many sq ft does a roll of ice and water shield cover?

A 36 in × 66.7 ft roll of GAF StormGuard is 200 sq ft before laps.[3] Laid in courses lapped 3 in, each 66.7 ft course covers (36 − 3) × 66.7 ÷ 12 = 183.43 sq ft of roof, less the end laps.[2][3]

How wide is ice and water shield?

GAF StormGuard comes in 36 in rolls, which is why a valley takes one roll width centered on it.[2][3]

How many square feet does a roll of 30 lb felt cover?

TAMKO's No. 30 felt comes in 36 in × 72 ft rolls that cover 204 sq ft laid by its instructions; No. 15 comes in 36 in × 144 ft rolls that cover 408 sq ft.[6]

Does ice and water shield go in the valleys?

GAF's instructions center it in each valley from the bottom up, each piece lapping the one below by at least 6 in and the top running past the valley's peak.[2] The calculator counts one roll width down every foot of valley.

Is an ice barrier required everywhere?

No. The code requires it where the jurisdiction records a history of ice forming along the eaves; your building department can tell you whether yours does.[1] The ice dams page explains how the ice forms.

Methodology & sources

The eave rule, the steep-slope minimum, the double underlayment and the minimum slope are from the 2024 IRC, Chapter 9. The leak barrier's reach past the wall, its laps, piece length and valley method are from GAF's StormGuard application instructions, and its roll from the StormGuard data sheet. FeltBuster's roll and laps are from GAF's sell sheet and instructions, and the felt coverage from TAMKO's underlayments brochure. The rest is the geometry above, tested on every build. Other makers' rolls and laps differ: enter theirs as another roll.

Sources

  1. [1] International Code Council. 2024 International Residential Code, Chapter 9: Roof Assemblies (Oct 2026 version). Sections R905.1.1, R905.1.2, R905.2.2. Retrieved Oct 28, 2026. codes.iccsafe.org
  2. [2] GAF. StormGuard Film-Surfaced Leak Barrier Application Instructions (RESUL192). Eaves & Rakes, step 2; Valleys, Hips & Ridges, step 1, Eaves & Rakes, step 8, Eaves & Rakes, steps 7, 9 and 10, Valleys, Hips & Ridges, steps 2 and 6. Retrieved Nov 19, 2026. gaf.com
  3. [3] GAF. StormGuard Film-Surfaced Leak Barrier data sheet (RESUL116-0825). Retrieved Oct 21, 2026. gaf.com
  4. [4] GAF. FeltBuster Synthetic Roofing Felt sell sheet (RESUL183-0125). Retrieved Oct 21, 2026. gaf.com
  5. [5] GAF. FeltBuster installation instructions (#498, 6/19). Retrieved Oct 21, 2026. gaf.com
  6. [6] TAMKO. TAMKO Underlayments brochure. Asphalt Saturated Felts, Product Data (p. 2). Retrieved Nov 19, 2026. tamko.com

Change log: first published November 25, 2026.

Related

By Marko Visic, BSc Physics. Updated November 25, 2026.